Conductor : bare copper conductor, fine wired stranded, class 5
Test voltage : 2500 V
Nominal voltage : Uο/U = 300/500 V
Insulation : PVC compound TI1 acc. to IEC 60227-3 / HD 21.3 S3 / DIN VDE 00281 part 3
ambient temperature at storage : up to 40 °C
Standards : HRN HD 21.3 S3 IEC 60227-3
Place of Origin : Guangzhou, China
Brand Name : SUNWIN
Certification : ISO9001, ISO14001, OHSAS18001
MOQ : Negotiable
Price : Negotiable
Packaging Details : 100 m / tied, or customized
Delivery Time : 10 day
Payment Terms : 30% deposit, the balance is settled on the delivery date
Supply Ability : 100,000 m / month
Multi Core Heat Resistant Electrical Wire 4 Core Insulated Copper Wire
Application
Flexible insulated conductor for wiring within electrical devices, lighting fixtures, switching- and distribution boxes, i.e. as bridge junction. Laid in dry areas, in closed electrical-installation conduits only for signaling and control circuits. Not for direct application under plaster.
Standards
HRN HD 21.3 S3
IEC 60227-3
DIN VDE 0281 part 3
Description
Conductor: | bare copper conductor, fine wired stranded, class 5 acc. to IEC 60228 / HD 383 / DIN VDE 0295 (nominal diameter 0,20 mm) | |
Insulation: | PVC compound TI1 acc. to IEC 60227-3 / HD 21.3 S3 / DIN VDE 00281 part 3 | |
Conductor colour identification: | acc. to IEC 60446 i.e. EN 60446 (corresponding to DIN VDE 0293) | |
possible insulation colours: | ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | |
- yellow-green colour used only for protecting conductor, and green and yellow ones are permitted only if allowed by security regulations, i.e. if they can not get mixed up with the yellow-green conductor | ||
- blue colour is used for neutral conductor, black and brown are applied for alternating current phase conductorse. |
Temperature
during installation: | +5 °C up to+70 °C |
fixed installed: | -30 °C up to+70 °C |
at short circuit of max. 5 s: | up to 160 °C |
ambient temperature at storage: | up to 40 °C |
Nominal voltage: | Uο/U = 300/500 V |
Test voltage: | 2000 V |
Minimal inner bending radius: | 4D |
Behaviour in fire: | IEC 60332- |
Dimensions – conductor cross-section | Construction of individual conductor | External diameter | Insulation thickness | Conductor resistance at 20 °C | Specific. el. resistance of insulation at 70°C | Cu weight | Cable weight | Permitted stress | Packing* |
nominal | min-max. | nominal | max. | min. | approx. | max. | |||
mm² | n x mm | mm | mm | Ω/km | MΩkm | kg/km | kg/km | N | |
0,5 | 16 x 0,20 | 2,1 - 2,5 | 0,6 | 39,0 | 0,013 | 4,8 | 10 | 8 | c.100, c.200 |
0,75 | 24 x 0,20 | 2,2 - 2,7 | 0,6 | 26,0 | 0,011 | 7,2 | 12 | 11 | c.100, c.200 |
1 | 32 x 0,20 | 2,4 - 2,8 | 0,6 | 19,5 | 0,010 | 9,6 | 14 | 15 | c.100, c.200 |
*) Packing: c.100 = coil 100 m , c.200 = coil 100 m
![]() |